M350 Starter
For use with low and medium voltage wound rotor motors from 200kW to
750kW, maximum rotor volts = 1500 V
Overview
The M350 is a 2 stage liquid resistance starter, each stage replacing
the equivalent of approximately 5 stages of fixed resistance.
The resistance units comprise electrodes (either 2 or 3) immersed
in electrolyte, contained within a 350 litre stainless steel tank. The
number of electrodes used is determined by the kW rating of the
motor, the number of starts per hour and the run-up time.
The principle of operation is based on the difference in resistivity
between the liquid electrolyte and its vapour contained in an
electrode chamber.
The passage of the initial rotor current causes
immediate partial vaporisation of the electrolyte and instantaneously
adjusts resistance and starting torque to optimum value.
During run-up, the thermal interchange which occurs decreases the
resistance and a timed contactor then short circuits the low residual
resistance.
The progressive decrease in resistance provides smooth and
continuous acceleration, hence the motor reaches full speed in the
shortest possible time with the absence of mechanical stress.
As the resistance decreases in direct relation to the motor speed,
the possibility of operator misuse is minimised and motor burn-out
problems are resolved.
Flexibility
M350 starters are easily adjustable on-site to meet changes in torque
or load. This is achieved by altering the electrolyte strength.

Environmental Stability
A layer of oil is floated on top of the electrolyte to form a seal which not only
minimises evaporation, but eliminates contamination from the atmosphere.
In locations with severe dust conditions such as mines, quarries and rubber mills
laden with carbon black, no additional protection is required.
Climate Conditions
Whether in the snow fields, or the desert regions of the outback, M350 starters
are operating almost maintenance free. Their only requirement is the need to
occasionally top them up with drinking water (pH = 7 to 9) every 12 months or so.
Availability
For ratings up to 750 kW very quick deliveries can be achieved as all components
required for construction are available ex-stock.
M350 Ratings
M350 starters are designed to meet the starting torque requirements of the
application and the starting duty (starting time and starts per hour) specified by
the user. The ratings given to M350 starters are therefore variable and application
dependant.
| Starter Model |
Nominal motor kW rating at starting torque of; |
| Single motor drives |
0.7 x FLT |
1.0 x FLT |
1.4 x FLT |
2.0 x FLT |
| M350/2 |
500 |
355 |
250 |
185 |
| M350/3 |
750 |
650 |
450 |
315 |
Notes: Nominal ratings only, based on 4 consecutive starts followed by 2 starts per hour from hot.
- Actual ratings will depend on start torque and run up time required.
- FLT = Full Load Torque otherwise refered to as Motor Rated Torque
|